4–7 Jun 2018
IHEP
Asia/Shanghai timezone
Young Engineers are encouraged to attend the open courses in 4th June. You can sign up when registering.

Status of EAST 3.5 K subcooling helium cryogenic sytem

Not scheduled
15m
Main building (IHEP)

Main building

IHEP

Beijing

Speaker

志刚 朱(中国科学院等离子体物理研究所)

Description

To obtain high operating current and magnetic fields of Experimental Advanced Superconducting Tokomak (EAST), it is a good choice to lower the operating temperature of the toroidal field (TF) coils. Beside 4.5 K refrigeration mode, the EAST helium refrigerator has the ability to provide a refrigeration capacity of 1050W at 3.5 K, based on warm compression with cold recovery. It consists of liquid helium Dewar, counter-flow heat exchanger, J-T valve, oil ring pump and so on. The oil ring pump was converted from the SKA303 series liquid ring pump, in particular shaft sealing to decrease the risk of air in-leaks. The EAST sub-cooling helium system was tested twice in cool-down experiments. It took only about one hour to cool down from 4.5 K to 3.5 K. The presentation will give an overview of this subcooling helium system and its last operation performance.