A simple cosmic ray stand for testing sampling scintillating fiber calorimeter module has been constructed. The measurement and analyses method is reported. A module of sampling scintillating fiber calorimeter from KLOE (INFN, Italy) is tested by using cosmic ray and the preliminary results for time resolution (252ps) and spacial resolution (4.1cm) are obtained.

References
| [1] |
. Breskin A. Nuclear Instrument and Methods , 1997 , A389 :12. Okusawa T et al . Nuclear Instrument and Methods , 2000 , A440 :3483. DeSalvo R et al . Nuclear Instrument and Methods , 1992 , A315 :3754. Kirtkby J . CERN-EP/87/605. Ambrosio C D et al . CERN-PPE/96-65“Particale Tracking with Scintil-lating Fibers”6. BAI J Z et al . Nuclear Instruments and Methods 1994 , A344 :3197. CHI Shao-Peng et al . HEP NP , 2003 , 27(3) :257 (in Chinese)(迟少鹏等. 高能物理与核物理,2003 ,27 (3) :257)8. CERN Program Library Writeup Q121 , PAW ( Physics Analysis Work-station)9. Antonelli M et al . ICHEP’96 , Warsaw , Juli 199610. Adinolfi M et al . N. I.M. , 2002 , A482 :36411. Hessey N et al . ATL-MUON-98-266
|