Abstract:
The effects of the parameters of RF system to electron beam intensity in Hefei storage ring are discussed in this paper. There appeared significant deviation respect to bean ideal orbit in the closed orbit distortion correction experiment, and therefore, necessary adjustments have been carried out for RF system parameters, such as frequency, cavity temperature, etc., to meet the requirement of intense beam injection. And the work have guidance effect to reconstruction of RF system in Phase Ⅱ project of Hefei storage ring.

References
| [1] |
. DAI Jian-Ping.Thesis for Ph.D Degree.Hefei:Published by Universi ty of Science and Technology of China,1997(in Chinese)(戴建枰.博士论文.中国科学技术大学出版社,1997)2. SUN Bao-Gen,HE Duo-Hui et al.HEP NP,2002,26(4):416—422(in Chinese)(孙葆根,何多慧等.高能物理与核物理,2002,26(4):416—422)3. LI Jing-Yi,LI Wei-Min et al.Development of Orbit Correction System of HLS Storage Ring.In:APAC2001,Spt.2001,Beijing(to be published)4. LIJing Yi,LIU Gong-Fa et al.Closed Orbit Correction of HLS Storage Ring.In:Proceedings of PAC 2001,Chicago,USA ,Jun.2001:1255—12575. Wilson P B.High Energy Electron Linac:Application to Storage Ring RF System and Linear Colliders.SLAC PUB 2884,Feb.1982(A)6. ZHAO Zheng-Tang,PAN Wei-Min et al.Design of a Copper Cavity for HLS.In:Proceedings of PAC 2001,Chicago,USA ,Jun.2001:1201—1203
|