Developments in accelerator mass spectrometry (AMS) method for182Hf

  • The present detection limit for182Hf at CIAE HI-13 AMS systems could not satisfy various applications (e. g. detection of a nearby supernovae signal). Therefore, techniques were developed in this work to improve the AMS measurement of182Hf mainly on building a new injector and using a method that based on solid-phase reaction for the preparation of HfF4samples from HfO2. The experimental results show that mass resolution of the injector can reached 630, and the F/O- and beam current of180HfF5for HfF4samples produced by dry method is about 2—3 times and 1.5 times of that by previously method, respectively.
  • 加载中
  • [1] . Vockenhuber C, Oberli F, Bichler M et al. Phys. Rev. Lett.,2004, 93(17): 01725012. Vockenhuber C, Bichler M, Golser R et al. Nucl. Instrum.Methods B, 2004, 223-224: 823-8283. Vockenhuber C, Feldstein C, Paul M et al. New Astr. Rev.,2004, 48: 161-1644. QIU Jiu-Zi, JIANG Shan, HE Ming et al. Nucl. Instrum.Methods B, 2007, 259: 246-2495. Vockenhuber C, Bergmaier A, Faestermann T et al. Nucl.Instrum. Methods B, 2007, 259: 250-2556. Winkler S, Fi eld L K, Tims S G et al. Nucl. Instrum.Methods B, 2007, 259: 256-2597. Winkler S, Fi eld L K, Tims S G et al. Nucl. Instrum.Methods B, 2007, 259: 260-264
  • 加载中

Get Citation
TUO Fei, HE Ming, SHEN Hong-Tao, WU Shao-Yong, HU Yue-Ming, BAO Yi-Wen, OUYANG Ying-Gen, YOU Qu-Bo, DOU Yu-Ling and JIANG Shan. Developments in accelerator mass spectrometry (AMS) method for 182Hf[J]. Chinese Physics C, 2008, 32(S2): 201-204.
TUO Fei, HE Ming, SHEN Hong-Tao, WU Shao-Yong, HU Yue-Ming, BAO Yi-Wen, OUYANG Ying-Gen, YOU Qu-Bo, DOU Yu-Ling and JIANG Shan. Developments in accelerator mass spectrometry (AMS) method for 182Hf[J]. Chinese Physics C, 2008, 32(S2): 201-204. shu
Milestone
Received: 2008-07-17
Revised: 1900-01-01
Article Metric

Article Views(5717)
PDF Downloads(586)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
    通讯作者:陈斌, bchen63@163.com
    • 1.

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Email This Article

    Title:
    Email:

    Developments in accelerator mass spectrometry (AMS) method for182Hf

      Corresponding author:TUO Fei,

      Abstract:The present detection limit for182Hf at CIAE HI-13 AMS systems could not satisfy various applications (e. g. detection of a nearby supernovae signal). Therefore, techniques were developed in this work to improve the AMS measurement of182Hf mainly on building a new injector and using a method that based on solid-phase reaction for the preparation of HfF4samples from HfO2. The experimental results show that mass resolution of the injector can reached 630, and the F/O- and beam current of180HfF5for HfF4samples produced by dry method is about 2—3 times and 1.5 times of that by previously method, respectively.

        HTML

      Reference (1)

      目录

      /

        Return
        Return
          Baidu
          map