High Sensitivity Beam Phase Measurement System for Isochronous Cyclotron
- Received Date:2006-07-11
- Accepted Date:2006-08-28
- Available Online:2007-03-05
Abstract:The beam phase measurement system in the HIRFL is introduced. Based on the double-balanced mixer principle using rf-signal mixing and filtering techniques, a stable and sensitive phase measurement system has been developed. The phase history of the ion beam is detected by using a set of capacitive pick-up probes installed in the cyclotron. The phase information of the measurement is necessary for tuning to obtain a optimized isochronous magnetic field which induces to maximize the beam intensity and to optimize the beam quality. The result of the phase measurement is reliable and the accurancy reaches ±0.5°.

Abstract
HTML
Reference
Related
PDF










DownLoad: