| [1] |
WANG Shu-Hong,PEI Guo-Xi,CHI Yun-Long,CHEN Yan-Wei,CAO Jian-She,KONG Xiang-Cheng,ZHAO Feng-Li,HOM Mi,CHEN Zhi-Bi,LIU Wei-Bin,DENG Bing-Lin,GENG Zhe-Qiao,PEI Shi-Lun,SHEN Li,LE Qi,YE Qiang. BEPCⅡ Linac Beam Commissioning and Operation. Chinese Physics C, 2008, 32(S1): 215-217. |
| [2] |
ZHAO Xiao-Yan,CAO Jian-She,WANG Lin,YUE Jun-Hui,YE Qiang,SUI Yan-Feng,ZHAO Ying,MA Hui-Zhou,ZHAO Jing-Xia,ZHANG Guo-Qing,ZHAO Zheng,Zhang Lei. Beam Loss Monitoring System of BEPCⅡ and Its First Application. Chinese Physics C, 2008, 32(S1): 80-82. |
| [3] |
JIAO Yi,ZHOU De-Min,WANG Jiu-Qing,QIN Qing,XU Gang,FANG Shou-Xian. Application of Frequency Map Analysis to the BEPCⅡ Lattice. Chinese Physics C, 2007, 31(6): 586-592. |
| [4] |
JIN Da-Peng,GUO Ya-Nan,WANG Yi-Fang,WU Ling-Hui,LIU Zhen-An,ZHAO Di-Xin,YU Zhong-Qiang. Monte Carlo Simulation of the BEPCⅡ/BEPCⅢ Backgrounds——Touschek Effects. Chinese Physics C, 2006, 30(5): 449-453. |
| [5] |
YUE Jun-Hui,MA Li,CAO Jian-She,ZHANG Lei. The Experiments of Transverse Feedback System on the BEPC. Chinese Physics C, 2006, 30(2): 163-165. |
| [6] |
WEI Yuan-Yuan,Qin Qing. Application of Response Matrix at the BEPC Storage Ring. Chinese Physics C, 2006, 30(S1): 43-45. |
| [7] |
LI Jia-Cai,ZHANG Liang-Sheng,HU Chun-Liang,WU Yuan-Ming,CUI Xiang-Zong,LIU Zheng-Quan,ZHANG Shao-Ping,ZHOU Bao-Qing,ZHENG Lin-Sheng. Design and Performance Measurement of the 1GeV/c Multiparticle Magnetic Spectrometer in the BEPC-LINAC Test Beam. Chinese Physics C, 2005, 29(1): 55-61. |
| [8] |
WANG Jun-Hua,LIU Jian-Hong,SUN Bao-Gen,LI Wei-Min,LIU Zu-Ping,YANG Yong-Liang. Calibration of Turn-by-Turn System of HLS and Its Application. Chinese Physics C, 2004, 28(5): 544-548. |
| [9] |
JIN Da-Peng,LU Feng,GUO Ya-Nan,WANG Yi-Fang,WU Ling-Hui,LIU Zhen-An,YU Zhong-Qiang. Monte Carlo Simulation of the BEPCⅡ/BESⅢ Backgrounds—Beam-Gas Interactions. Chinese Physics C, 2004, 28(11): 1197-1202. |
| [10] |
SUN Sheng-Sen,SHEN Xiao-Yan,ZHENG Zhi-Peng,YAN Mu-Lin. Monte Carlo Study of K*(892) Mass Splitting at BEPCⅡ/BESⅢ. Chinese Physics C, 2004, 28(5): 463-468. |
| [11] |
HU Chun-Liang. Beam-Based Calibration System of BPM Offset on BEPC. Chinese Physics C, 2004, 28(2): 200-204. |
| [12] |
ZHAO Zheng,GUO Zhi-Yuan,LIU De-Kang,MA Li,QIN Qing,WANG Jiu-Qing,XU Gang. Bunch Length Measurement of BEPC with a Streak Camera. Chinese Physics C, 2003, 27(4): 359-362. |
| [13] |
LUO Yun,GUO Zhi-Yuan,ZHANG Chuang. Analysis of an Ion Induced Coupled Bunch Instability in BEPC. Chinese Physics C, 2001, 25(3): 258-263. |
| [14] |
MA Li,CAO JianShe,WANG Lin. Tune Measurements in the BEPC Storage Ring. Chinese Physics C, 2000, 24(8): 770-774. |
| [15] |
Ma Li,Shi Ping,Ye Kairong. Upgrade of BPM System for the BEPC Storage Ring. Chinese Physics C, 1998, 22(5): 475-480. |
| [16] |
Deng Jingkang,Shang Rencheng,Zhu Shengjiang,Xu Wang,Zhang Juping,Jin Qingzhen,Zhu Henian,Xia Shaojian,Yan Yonglian,Guo Yanan. Study on Polarization of BEPC Beam and a Polarimeter. Chinese Physics C, 1997, 21(6): 562-570. |
| [17] |
Li Yun,Wang Guangwei. Research of Bunch Lengthening of BEPC Ring by Many-Particle Simulation. Chinese Physics C, 1996, 20(10): 950-956. |
| [18] |
BES Collaboration. τ Mass Measurement at Beijing Electron Positron Collider (BEPC). Chinese Physics C, 1992, 16(10): 865-875. |
| [19] |
LIU Nian-Zong,ZHANG Cai-Di,ZHENG Lin-Sheng,HU Li-Dong,ZHAO Xiao-Jian,ZHONG Xue-Chu,DENG Hu,ZHU Shan-Gen,ZHANG Ge,ZHANG Zhu-Xiang,ZHANG Liang-Sheng,ZHOU Yong-Shen,XU Jian-Guo,TAN Yi-Ping,HAN Shu-Rong,HAN Ying,BAO Xiu-Min. The Test Beam on BEPC and Physics Works on It. Chinese Physics C, 1992, 16(11): 965-977. |
| [20] |
FANG Shou-Xian,CHEN Li-Min,CHEN Sen-Yu,CHEN Si-Yu,LIANG Xiu-Ru,ZHANG Chuang. IMPROVMENTS TO THE BEPC STORAGE RING LATTICE. Chinese Physics C, 1986, 10(2): 207-214. |