BaF2Used for Particle Identification in Intermediate Energy Heavy Ion Raactions

  • A detector telescope consisting of a BaF 2crystal and Si detectors is used to measure forwardly emitted products in 12C(46.7MeV/u)induced heavy ion reactions,both ΔE-E method and fast-slow correlation method are adopted in the particle identification.The response of BaF 2to various incident ions has been studied.
  • 加载中
  • [1] Harshaw/Filtrol SCINTILLATION PHOSPHOR Catalog, 1984.[2] M. Laval et al., Nucl. Instr. and Meth., 206(1983), 169.[3] G. Tzanakos et al., IEEE Trans. Nucl. Sci., ITS-37(1990), 1599.[4] T. Murakami et al., Nucl. Instr. and Meth., A253(1986), 163.[5] F. A. Beck, in Instrumentation for Heavy Ion Nuclear Research, Ed D. Shapira (Harwood Academic Publishers, 1985) Vol. 7, p. 129.[6] E. Dafni, Nucl. Instr. and Meth., A254(1987), 54.[7] S. Kubota et al., IEEE Trans. Nucl. Sci., NS-34(1987), 438.[8] A. L. Boonstra et al., GSI Scientific Report, (1989), 290.[9] Liu Guanhua et al., IMP Annual Report (1990).
  • 加载中

Get Citation
LIU Guan-Hua, GUO Zhong-Yan, ZHAN Wen-Long, ZHU Yong-Tai, HU Xiao-Qing, XI Hong-Fei, ZHOU Jian-Qun and FENG En-Pu. BaF 2Used for Particle Identification in Intermediate Energy Heavy Ion Raactions[J]. Chinese Physics C, 1992, 16(11): 1030-1034.
LIU Guan-Hua, GUO Zhong-Yan, ZHAN Wen-Long, ZHU Yong-Tai, HU Xiao-Qing, XI Hong-Fei, ZHOU Jian-Qun and FENG En-Pu. BaF 2Used for Particle Identification in Intermediate Energy Heavy Ion Raactions[J]. Chinese Physics C, 1992, 16(11): 1030-1034. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(3584)
PDF Downloads(453)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
    通讯作者:陈斌, bchen63@163.com
    • 1.

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Email This Article

    Title:
    Email:

    BaF2Used for Particle Identification in Intermediate Energy Heavy Ion Raactions

      Corresponding author:LIU Guan-Hua,
    • Institute of Modern Phsics,Academia Sinica,Lanzhou 730000

      Abstract:A detector telescope consisting of a BaF2crystal and Si detectors is used to measure forwardly emitted products in12C(46.7MeV/u)induced heavy ion reactions,both ΔE-E method and fast-slow correlation method are adopted in the particle identification.The response of BaF2to various incident ions has been studied.