Effect of Spectroscopy Amplifier Parameter on Identification of Light Charged Particles by Pulse Shaping Analysis Method

Get Citation
WANG Jin-Chuan, XI Hong-Fei, GUO Zhong-Yan, ZHAN Wen-Long, ZHU Yong-Tai, ZHOU Jian-Qun, LOU Guan-Hua and SU Hong. Effect of Spectroscopy Amplifier Parameter on Identification of Light Charged Particles by Pulse Shaping Analysis Method[J]. Chinese Physics C, 1993, 17(1): 69-77.
WANG Jin-Chuan, XI Hong-Fei, GUO Zhong-Yan, ZHAN Wen-Long, ZHU Yong-Tai, ZHOU Jian-Qun, LOU Guan-Hua and SU Hong. Effect of Spectroscopy Amplifier Parameter on Identification of Light Charged Particles by Pulse Shaping Analysis Method[J]. Chinese Physics C, 1993, 17(1): 69-77. shu
Milestone
Received: 1900-01-01
Revised: 1900-01-01
Article Metric

Article Views(3865)
PDF Downloads(508)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
    通讯作者:陈斌, bchen63@163.com
    • 1.

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Email This Article

    Title:
    Email:

    Effect of Spectroscopy Amplifier Parameter on Identification of Light Charged Particles by Pulse Shaping Analysis Method

      Corresponding author:WANG Jin-Chuan,
    • Institute of Modern Physics,Academia Sinica,Lanzhou 730000

      Abstract:The pulse shaping analysis method is applied to identify the light charged particles emitted from12C(46.7/MeV/u)+58Ni reaction by using the CsI(T1) scintillator detector with photodiode readout.In the experiment,it is found that the particle identification greatly depends on the choice of spectroscopy amplifier shaping time constant.The problem is investigated on the basis of Laplace transformation method.The experimental phenomena have been successfully explanined.

        HTML

      Reference (1)

      目录

      /

        Return
        Return
          Baidu
          map