| [1] |
Zhao-Min Wang,Yu-Hong Yu,Zhi-Yu Sun,Ke Yue,Duo Yan,Yong-Jie Zhang,Yong Zhou,Fang Fang,Wen-Xue Huang,Jun-Ling Chen. Temperature dependence of the plastic scintillator detector for DAMPE. Chinese Physics C, 2017, 41(1): 016001.doi:10.1088/1674-1137/41/1/016001 |
| [2] |
Da-Li Zhang,Hong Lu,Huan-Yu Wang,Xin-Qiao Li,Yan-Bing Xu,Zheng-Hua An,Hui Wang,Feng Shi,Ping Wang,Xiao-Yun Zhao,. Beam test of CSES silicon strip detector module. Chinese Physics C, 2017, 41(5): 056101.doi:10.1088/1674-1137/41/5/056101 |
| [3] |
Cheng Zhang,Zu-Hao Li,Zhi-Cheng Tang,Suzan Basegmez du Pree,Shao-Wen Zhang,Xue-Qiang Wang,Min Yang,Guo-Ming Chen,He-Sheng Chen. Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter. Chinese Physics C, 2016, 40(9): 096204.doi:10.1088/1674-1137/40/9/096204 |
| [4] |
Yi Liu,Yunpeng Lu,Xudong Ju,Qun Ou-Yang. Test of a fine pitch SOI pixel detector with laser beam. Chinese Physics C, 2016, 40(1): 016202.doi:10.1088/1674-1137/40/1/016202 |
| [5] |
Yong Zhang,Jun-Xia Wu,Guang-Yu Zhu,Huan Jia,Zong-Heng Xue,Hai Zheng,Hong-Ming Xie,Xin-Cai Kang,Yuan He,Lin Li,Jean Claude Denard. Capacitive beam position monitors for the low-βbeam of the Chinese ADS proton linac. Chinese Physics C, 2016, 40(2): 027003.doi:10.1088/1674-1137/40/2/027003 |
| [6] |
JIAO Yi,XIAO Ou-Zheng. Beam dynamics studies of the photo-injector in low-charge operation mode for the ERL test facility at IHEP. Chinese Physics C, 2014, 38(6): 067003.doi:10.1088/1674-1137/38/6/067003 |
| [7] |
LI Zu-Hao,XU Wei-Wei,WANG Ling-Yu,ZHANG Cheng,TANG Zhi-Cheng,YAN Qi,YANG Min,LÜ Yu-Sheng,CHEN Guo-Ming,CHEN He-Sheng. Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter. Chinese Physics C, 2014, 38(5): 056203.doi:10.1088/1674-1137/38/5/056203 |
| [8] |
BAI Sha,GAO Jie. Propagation of a beam halo in accelerator test facility 2 at KEK. Chinese Physics C, 2013, 37(5): 057005.doi:10.1088/1674-1137/37/5/057005 |
| [9] |
LIU Mei,DAI Hong-Liang,QI Hui-Rong,ZHUANG Bao-An,ZHANG Jian,LIU Rong-Guang,ZHU Qi-Ming,OUYANG Qun,CHEN Yuan-Bo,JIANG Xiao-Shan,WANG Ya-Jie,LIU Peng,CHANG Guang-Cai. Beam test of a one-dimensional position sensitive chamber on synchrotron radiation. Chinese Physics C, 2013, 37(10): 108001.doi:10.1088/1674-1137/37/10/108001 |
| [10] |
SU Jia-Hang,DU Ying-Chao,HUA Jian-Fei,ZHENG Shu-Xin,QIU Jia-Qi,YANG Jin,HUANG Wen-Hui,CHEN Huai-Bi,TANG Chuan-Xiang. Design and cold test of a rectangular cavity beam position monitor. Chinese Physics C, 2013, 37(1): 017002.doi:10.1088/1674-1137/37/1/017002 |
| [11] |
LI Zu-Hao,WANG Ling-Yu,XU Wei-Wei,CHEN Guo-Ming,CHEN He-Sheng,. Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter. Chinese Physics C, 2013, 37(2): 026201.doi:10.1088/1674-1137/37/2/026201 |
| [12] |
LU Chen-Gui,DUAN Li-Min,XU Hu-Shan,YANG He-Run,HU Rong-Jiang,ZHANG Jin-Xia,LI Zu-Yu. Test and simulation of a MICROMEGAS detector. Chinese Physics C, 2011, 35(11): 1033-1036.doi:10.1088/1674-1137/35/11/010 |
| [13] |
BAI Sha,GAO Jie. Simulation of beam size multiknobs correction at the Accelerator Test Facility 2 at KEK. Chinese Physics C, 2011, 35(4): 397-401.doi:10.1088/1674-1137/35/4/014 |
| [14] |
RUAN Yu-Fang,XU Tao-Guang,FU Shi-Nian. Design and simulation of a beam position monitor for the high current proton linac. Chinese Physics C, 2009, 33(3): 240-244.doi:10.1088/1674-1137/33/3/015 |
| [15] |
FENG Lang,GE Yu-Cheng,WANG He,FAN Feng-Ying,QIAO Rui,LU Fei,SONG Yu-Shou,ZHENG Tao,YE Yan-Lin. New test and analysis of position-sensitive-silicon-detector. Chinese Physics C, 2009, 33(1): 50-53.doi:10.1088/1674-1137/33/1/011 |
| [16] |
WANG Shu-Hong,PEI Guo-Xi,CHI Yun-Long,CHEN Yan-Wei,CAO Jian-She,KONG Xiang-Cheng,ZHAO Feng-Li,HOM Mi,CHEN Zhi-Bi,LIU Wei-Bin,DENG Bing-Lin,GENG Zhe-Qiao,PEI Shi-Lun,SHEN Li,LE Qi,YE Qiang. BEPCⅡ Linac Beam Commissioning and Operation. Chinese Physics C, 2008, 32(S1): 215-217. |
| [17] |
LI Jia-Cai,ZHANG Liang-Sheng,HU Chun-Liang,WU Yuan-Ming,CUI Xiang-Zong,LIU Zheng-Quan,ZHANG Shao-Ping,ZHOU Bao-Qing,ZHENG Lin-Sheng. Design and Performance Measurement of the 1GeV/c Multiparticle Magnetic Spectrometer in the BEPC-LINAC Test Beam. Chinese Physics C, 2005, 29(1): 55-61. |
| [18] |
LI Jia-Cai1,WU Yuan-Ming1,CUI Xiang-Zong1,ZHANG Liang-Sheng1,ZHOU Bao-Qing1,LIU Zheng-Quan1,ZHANG Shao-Ping1,LIU Shi-Xing2,SUN Chang-Chun1,SHEN Ji2,YIN Ze-Jie2,ZHANG Yong-Ming,,,,. A Test Beam Upgrade Based on the BEPC-LINAC. Chinese Physics C, 2004, 28(12): 1269-1277. |
| [19] |
WANG Shu-Hong,GU Peng-Da,WANG Jiu-Qing,LIU Yu-Cheng,PEI Guo-Xi,PEI Shi-Lun,ZHOU Zu-Sheng,LIU Wei-Bin. Studies on Optimizing Beam Optics and Orbit Correction for BEPCⅡ-Linac. Chinese Physics C, 2003, 27(2): 173-177. |
| [20] |
Liu Nianzong,Zhang Caidi,Zheng Linsheng,Hu Lidong,Zhao Xiaojian,Zhong Xuechu,Deng Hu,Zhu Shangen,Zhang Ge,Zhang Zhuxiang,Zhang Liangsheng,Zhou Yongshen,Xu Jianguo,Tan Yiping,Han Shurong,Han Ying,Bao Xiumin. Test Beam on the Beijing Electron Positron Collider (BEPC) and Physics Work on It. Chinese Physics C, 1992, 16(S4): 355-366. |