| [1] |
Hui-Yin Wu,Sheng-Ying Zhao,Xiao-Dong Wang,Xian-Ming Zhang,Hui-Rong Qi,Wei Zhang,Ke-Yan Wu,Bi-Tao Hu,Yi Zhang. Discriminating cosmic muons and X-rays based on rise time using a GEM detector. Chinese Physics C, 2016, 40(8): 086001.doi:10.1088/1674-1137/40/8/086001 |
| [2] |
Xu-Dong Ju,Ming-Yi Dong,Yi-Chen Zhao,Chuan-Xing Zhou,Qun Ou-Yang. Design and optimization of resistive anode for a two-dimensional imaging GEM detector. Chinese Physics C, 2016, 40(8): 086004.doi:10.1088/1674-1137/40/8/086004 |
| [3] |
LIU Long,HUANG Yang,XU Qing,YAN Ling-Tong,LI Li,FENG Song-Lin,FENG Xiang-Qian. Attenuation correction ofL-shell X-ray fluorescence computed tomography imaging. Chinese Physics C, 2015, 39(3): 038203.doi:10.1088/1674-1137/39/3/038203 |
| [4] |
FENG Zhao-Dong,JIANG Peng,ZHANG Hong-Kai,ZHAO Bo-Zhen,QIN Xiu-Bo,WEI Cun-Feng,LIU Yu,WEI Long. Performance assessment of CsI(Tl) screens on varioussubstrates for X-ray imaging. Chinese Physics C, 2015, 39(7): 078202.doi:10.1088/1674-1137/39/7/078202 |
| [5] |
HE Li,DENG Zhi,LIU Yi-Nong,LI Yu-Lan. Development of a multi-channel readout ASIC for a fast neutron spectrometer based on GEM-TPC. Chinese Physics C, 2014, 38(10): 106101.doi:10.1088/1674-1137/38/10/106101 |
| [6] |
ZHAO Bo-Zhen,QIN Xiu-Bo,FENG Zhao-Dong,WEI Cun-Feng,CHEN Yan,WANG Bao-Yi,WEI Long. Performance evaluation of CsI screens for X-ray imaging. Chinese Physics C, 2014, 38(11): 116003.doi:10.1088/1674-1137/38/11/116003 |
| [7] |
ZHANG Yu-Lian,QI Hui-Rong,HU Bi-Tao,FAN Sheng-Nan,WANG Bo,LIU Mei,ZHANG Jian,LIU Rong-Guang,CHANG Guang-Cai,LIU Peng,OUYANG Qun,CHEN Yuan-Bo,YI Fu-Ting. Investigation of GEM-Micromegas detector on X-ray beam of synchrotron radiation. Chinese Physics C, 2014, 38(4): 046001.doi:10.1088/1674-1137/38/4/046001 |
| [8] |
LI Zhe,TUO Xian-Guo,YANG Jian-Bo,LIU Ming-Zhe,CHENG Yi,WANG Lei. Statistical distribution based detector response function ofSi (PIN) detector for Kαand KβX-ray. Chinese Physics C, 2013, 37(1): 018202.doi:10.1088/1674-1137/37/1/018202 |
| [9] |
LU Bo,CUI Wei-Wei,WANG Yu-Sa,ZHU Yue,ZHANG Yi,XU Yu-Peng,CHEN Yong,HUO Jia,LI Wei,HAN Da-Wei,LI Mao-Shun,YANG Yan-Ji,WANG Juan,CHEN Tian-Xiang,HU Wei,LI Cheng-Kui,LIU Xiao-Yan. Design and optimization of the readout system for X-ray CCDs. Chinese Physics C, 2012, 36(9): 846-850.doi:10.1088/1674-1137/36/9/009 |
| [10] |
FAN Rui-Rui,CHEN Yuan-Bo,OUYANG Qun,LIU Rong-Guang,LIU Peng,QI Hui-Rong,ZHANG Jian,ZHAO Ping-Ping,ZHAO Dong-Xu,ZHAO Yu-Bin,ZHANG Hong-Yu,SHENG Hua-Yi,DONG Li-Yuan,. Study of measuring methods on spatial resolution of a GEM imaging detector. Chinese Physics C, 2012, 36(3): 228-234.doi:10.1088/1674-1137/36/3/007 |
| [11] |
JIA Quan-Jie,CHEN Yu,LI Gang,JIANG Xiao-Ming. Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution. Chinese Physics C, 2012, 36(3): 267-274.doi:10.1088/1674-1137/36/3/014 |
| [12] |
LI Xian-Li,ZHANG Yun-Long,QIAN Hao,XU Zi-Zong,WANG Xiao-Lian. Delay line readout of a large dimension multi-wire proportional chamber. Chinese Physics C, 2012, 36(6): 519-524 .doi:10.1088/1674-1137/36/6/007 |
| [13] |
DENG Biao,YANG Qun,XIE Hong-Lan,DU Guo-Hao,XIAO Ti-Qiao. First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline. Chinese Physics C, 2011, 35(4): 402-404.doi:10.1088/1674-1137/35/4/015 |
| [14] |
YAN Qiu-Rong,ZHAO Bao-Sheng,LIU Yong-An,YANG Hao,SHENG Li-Zhi,WEI Yong-Lin. Two-dimensional photon counting imaging detector based on a Vernier position sensitive anode readout. Chinese Physics C, 2011, 35(4): 368-373.doi:10.1088/1674-1137/35/4/009 |
| [15] |
XU Rui,LIU Chao-Pei. Instrumentation of coherent X-ray imaging and the primary experimental results. Chinese Physics C, 2010, 34(2): 224-226.doi:10.1088/1674-1137/34/2/013 |
| [16] |
TAN Gao,WANG Hua-Qiao,CHEN Yu,YUAN Qing-Xi,LI Gang,ZHANG Xiao-Dan,ZHU Pei-Ping,ZHONG Xiu-Feng,TANG Jin-Tian. X-ray diffraction enhanced imaging study of intraocular tumors in human beings. Chinese Physics C, 2010, 34(2): 237-244.doi:10.1088/1674-1137/34/2/016 |
| [17] |
HAN Li-Ying,LI Qi-Te,Q. Faisal,GE Yu-Cheng,LIU Hong-Tao,YE Yan-Lin. Study of a multi-wire proportional chamber with a cathode strip and delay-line readout. Chinese Physics C, 2009, 33(5): 364-368.doi:10.1088/1674-1137/33/5/009 |
| [18] |
Liangjun Cao,Huirong Qi,Jin Li,,,,. Design and Construction of a TPC Prototype based on GEM Detector Readout. Chinese Physics C, 2008, 32(1): 52-55.doi:10.1088/1674-1137/32/1/012 |
| [19] |
ZHOU Yi,LI Cheng. Research on the delay-line readout for GEM detectors. Chinese Physics C, 2008, 32(S2): 232-234. |
| [20] |
LI Cheng,SUN Yong-Jie,ZHOU Yi,AN Shao-Hui,XU Zi-Zong. A Prototype of X-Ray Imaging Based on the GEM Detector. Chinese Physics C, 2005, 29(1): 68-71. |