A large area plastic scintillation detector with 4-corner-readout
- Received Date:2015-08-24
- Accepted Date:2015-11-01
- Available Online:2016-05-05
Abstract:A 760 mm×760 mm×30 mm plastic scintillation detector viewed by photomultiplier tubes(PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and γ rays. A position-independent effective timeTeffhas been found, indicating this detector can be used as a TOF detector. The hit position can also be reconstructed by the time from the four corners. A TOF resolution of 236 ps and a position resolution of 48 mm have been achieved, and the detection efficiency has also been investigated.

Abstract
HTML
Reference
Related
PDF










DownLoad: