Abstract:
Beam Position Monitors (BPMs) for the low-
βbeam of the Chinese Accelerator Driven Subcritical system (CADS) Proton linac are of the capacitive pick-up type. They provide higher output signals than that of the inductive type. This paper will describe the design and tests of the capacitive BPM system for the low-
βproton linac, including the pick-ups, the test bench and the read-out electronics. The tests done with an actual proton beam show a good agreement between the measurements and the simulations in the time domain.

References
| [1] |
Y. He, et al, in Proceedings of IPAC (Spain, 2011) p. 2613 |
| [2] |
R. E. Shafer, AIP Conf. Proc., 212: 26 (1990) |
| [3] |
S. R. Smith, AIP Conf. Proc., 390: 50 (1997) |
| [4] |
T. Suwada et al, Nucl. Instrum. Methods A, 440: 307 (2000) |
| [5] |
T. Suwada, Nucl. Instrum. Methods A, 705: 7 (2013) |
| [6] |
N. Hayashi et al, Nucl. Instrum. Methods A, 677: 94 (2012) |
| [7] |
M. Bai et al, Nucl. Instrum. Methods A, 499: 372 (2003) |
| [8] |
P. Forck et al, Beam Position Monitors, in CERN Accelerator School on Beam Diagnostics, (2008) |
| [9] |
R. E. Shafer, in Proc. Beam Instr. Workshop (BIW), (Santa Fe 1993) p.303 |
| [10] |
M. Cohen-Solal, Phys. Rev. Spec. TOP - AC, 13: 032801 (2010) |
| [11] |
P. Strehl, Beam instrumentation and diagnostics (Berlin: Springer, 2006) p.156 |
| [12] |
P. Kowina et al, in Proceedings of DIPAC (Basel, Switzerland, 2009) p.35 |
| [13] |
www.cst.com |
| [14] |
Y. F. Ruan et al, Chinese Phys. C, 33(3): 240-244 (2009) |
| [15] |
User Manual, Libera Single Pass H, www. i-tech.si, (2013) |
Access
-