X
Advanced Search

A setup and analytical dose calculation model for solid-state sample irradiation using a microtron type e-beam accelerator

  • PurposeThis paper presents the development and implementation of a microtron-based setup for solid-state sample irradiation.
    MethodsThe fabrication of microtron components that extract 6 MeV electrons is detailed, enabling detailed studies of energy-dependent radiation effects.
    ResultsExperimental findings have led to a precise mapping of accelerated electron flux density, and subsequently, the establishment of uniform irradiation zones and real-time dose absorption control. Titanium carbide samples were irradiated using the bremsstrahlung of electrons from the microtron.
    ConclusionCalculations of absorbed doses from an extended bremsstrahlung source were conducted, considering key factors such as sample geometry and physical properties.
  • loading
  • Shakhboz Khasanov, Youwu Su, Renat Suleymanov, et al. A setup and analytical dose calculation model for solid-state sample irradiation using a microtron type e-beam acceleratorJ. Radiation Detection Technology and Methods, 2024, 8(4): 1568-1577. DOI: 10.1007/s41605-024-00483-8
    Citation: Shakhboz Khasanov, Youwu Su, Renat Suleymanov, et al. A setup and analytical dose calculation model for solid-state sample irradiation using a microtron type e-beam acceleratorJ. Radiation Detection Technology and Methods, 2024, 8(4): 1568-1577. DOI: 10.1007/s41605-024-00483-8