Speaker
DrEigen Gerald(University of Bergen)
Description
The gain of SiPMs increases with bias voltage and decreases with temperature. To operate SiPMs at stable gain, the bias voltage can be adjusted to compensate temperature changes. We have tested this concept with 30 SiPMs from three manufacturers (Hamamatsu, KETEK, CPTA) in a climate chamber at CERN varying the temperature from 1°C to 50°C. We built an adaptive power supply that used a linear temperature dependence of the bias voltage readjustment. With one selected bias voltage readjustment, we stabilized four SiPMs simultaneously. We fulfilled our goal of limiting the deviation from gain stability in the 20°C-30°C temperature range to less than ±0.5% for most of the tested SiPMs. We further studied afterpulsing for sensors with trenches.
Author
DrEigen Gerald(University of Bergen)
Co-authors
MrAre Traeet(University of Bergen)
DrJaroslav cvach(Institute of Physics of the ASCR)
MrJiri Kvasnicka(Institute of Physics of the ASCR)
DrJustas Zalieckas(University of Bergen)
MrPolak Ivo(Institute of Physics of the ASCR,)